  g-1 features ordering codes high-reliability pressure transmitter ? measuring for air, water, oil, etc. ? a variety of model according to field application - head type - din connector type - connector cable type ? adoption of suitable stainless steel diaphragm for temperature character ? 4~20ma transmission output by 2-wire TPS20 series TPS20 series(electric pressure transmitter) as high accuracy high reliable pressure transmitter using stainless steel diaphragm, is able to measure whole scale, 0.2~350 kg/cm2g and has absolute pressure, 0~30kg/  abs type. ? TPS20 description g gauge pressure ? pressure type a absolute pressure 1 head type ? type 2 din connector type 3 connector cable type t cable selection : 2m, 5m (separate goods) 1 0 - 0.2 m f/ m? 2 0 - 0.5 m f/ m? 3 * 0 - 1 m f/ m? 4 * 0 - 2 m f/ m? 5 * 0 - 5 m f/ m? 6 * 0 - 10 m f/ m? 7 * 0 - 20 m f/ m? 8 * 0 - 30 m f/ m? 9 0 - 50 m f/ m? a 0 - 100 m f/ m? c 0 - 200 m f/ m? f 0 - 300 m f/ m? h 0 - 350 m f/ m? m -760mmhg - 0 m f/ m? o -760mmhg - 1 m f/ m? q -760mmhg - 5 m f/ m? v -760mmhg - 10 m f/ m? x -760mmhg - 20 m f/ m? y -760mmhg - 30 m f/ m? z others p2 pt 1/2" ? process connection p8 pt 3/8 f8 pf 3/8" (standard) ? range t mark is possible for absolute pressure zz others ? pressure transmitter ? pressure type ? connector type ? pressure range ? process connection t in case of ordering only cable, code shall betps2i,tps2l, tps5i,tps5l, etc. option (connector cable) 2i 00 2l 5i 5l none itype 2m ltype 2m itype 5m ltype 5m measuring range allowable over pressure electric characteristic accuracy power supply output load resistance consumption power linearity hysteresis z e r o s p a n element c a s e using temp. / humidity temperature characteristic response time connection material range case protection weight -760mmhg ~ 0 to 30 kg/  a (compound pressure) 0~0.2 to 350 kg/  g (gauge pressure) 0~1.0 to 30 kg/  abs (absolute pressure) 300% of max. span 15v~35vdc 4-20ma dc 600 max 0.5w 0.3% f.s(linearity, hysteresis, repeatability) 0.3% f.s -10~50 e 0.3% f.s 50~70 e 0.5% f.s((except for -10~50 e )) 0.3% f.s -10~70 e , 5~95%rh 0.03%f.s 0.03%f.s (25 e std.) less 100ms pf 3/8(std.) (option : pt 3/8, pt 1/2) diaphragm : sus 316 sealing : sus 316 o-ring : fluorine rubber connection : sus316 refer to range table weatherproof approx. 320g (head type std.) specifications dimensions (unit : mm) * above connection is standard type (pf 3/8). head type din connector type connector cable type l type i type 105 ?30 pf3/8 106 59 ?26.8 pf3/8 ?22 pf3/8 119.5 ?22 pf3/8 132
high-reliability pressure transmitter diagnosis defect mounting / transportation / storage / repair g-2 connections TPS20 series kt - 302h recorders data loggers indicators converters controllers thyristor units transmitters temp. sensors a b c d e f g h thermo meters pressure gauges others i j k idp igp-10 / iap-10 kt - 502h cn-502h/ cn-501h ss - 5300 high-reliability pressure transmitter TPS20 series ? head type ? din connector type ? connector cable type 1 : l, 2 : l. : f.g 1 : l, 3 : ground 4 : l. 5 6 7 4 4 6 5 ]hur vsdq . 0 ? external connections TPS20 250 24vdc recorder terminal 4-20ma power 24vdc load 600 output 4-20ma 2wire ? mounting : when mounting this unit to pressure line, please use hexagon of connector instead of pipe wrench. also please do not use it where sharp vibration occurs ? transportation : as precision instrument, because drop or shock may cause mechanical trouble, please be careful during transportation. ? storage : please store it in the place without moisture, dust, vibration. ? repair : this unit is unnecessary for repair because detector has not the operating parts. internal parts are usually clean but it shall need repair according to the using condition. regular repair cycle should be done every year. in this case, please check as following clause. * please check external connector damages. * please check pressure connector, internal cleanness, corrosion. * after short circuit, please check isolated resistance between case and power supply. * please check zero/span and linearity by using standard pressure equipment. g t in case of disconnecting sensor in order for repair / checking, please operate as follows. ggy please replace the used o-ring. ggt please be care of sensor diaphragm element in order to avoid from damages. error situation diagnosis clause it is not outputting. output is strangely fluctuating. output value of zero point is largely different. does it power on? is wiring (+.-) correct? is not connection defective? is power normally supplied? is pressure correctly supplied? is there any problem in pressure line? is power normally supplied? is load resistance of receiving instrument in excess of 600? how about the transmitting distance to measuring point? is the line resistance large? (max. 600)


▲Up To Search▲   

 
Price & Availability of TPS20

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X